{"id":4293,"date":"2018-09-03T12:32:38","date_gmt":"2018-09-03T10:32:38","guid":{"rendered":"http:\/\/lifasa.com\/?page_id=4293"},"modified":"2018-11-14T15:22:27","modified_gmt":"2018-11-14T14:22:27","slug":"high-voltage-capacitor-banks-technical-note","status":"publish","type":"page","link":"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/","title":{"rendered":"High Voltage Capacitor Banks Technical Note"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling fusion-equal-height-columns\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-column-content-centered\"><div class=\"fusion-column-content\"><div class=\"fusion-text fusion-text-1 justificado\"><p>There are a series of elements and materials, as in the case of LV equipment, for its HV operation that must accompany our HV capacitors for their correct operation and for that of our installation\/network, as well as the rest of the equipment that compose it and that are in parallel operation with the capacitors that we want to put into service for the correction of the power factor (compensation of the consumption of Reactive Energy).<\/p>\n<p>The choice of one type of equipment or another, as well as its configuration, will depend not only on the final cost of the equipment, but will also be marked by the mains voltage, as well as the loading regime of our installation.<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\"><p>There are two types of banks, depending upon the mode of connection. First is 3 phase single star connected, which is suitable, where voltage is preferably low, say up to 6,6 kV. Other is 3 phase double star connected bank assembled with minimum 6 Nos of single phase units, preferably for systems where voltage is higher, say 11 kV and above.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-column-content-centered\"><div class=\"fusion-column-content\"><div class=\"fusion-image-element fusion-image-align-center in-legacy-container\" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><div class=\"imageframe-align-center\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"497\" height=\"353\" alt=\"Tipos de conexi\u00f3n en las bater\u00edas de condensadores de Alta Tensi\u00f3n\" title=\"grafico-baterias-condensadores-at\" src=\"https:\/\/lifasa.com\/wp-content\/uploads\/grafico-baterias-condensadores-at.jpg\" data-orig-src=\"http:\/\/lifasa.com\/wp-content\/uploads\/grafico-baterias-condensadores-at.jpg\" class=\"lazyload img-responsive wp-image-3660\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27497%27%20height%3D%27353%27%20viewBox%3D%270%200%20497%20353%27%3E%3Crect%20width%3D%27497%27%20height%3D%27353%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/lifasa.com\/wp-content\/uploads\/grafico-baterias-condensadores-at-200x142.jpg 200w, https:\/\/lifasa.com\/wp-content\/uploads\/grafico-baterias-condensadores-at-400x284.jpg 400w, https:\/\/lifasa.com\/wp-content\/uploads\/grafico-baterias-condensadores-at.jpg 497w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 800px) 100vw, 497px\" \/><\/span><\/div><\/div><\/div><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-3 justificado\"><h3>Direct three-phase connection.<\/h3>\n<p><span style=\"font-weight: 400;\">They are formed by the connection of 1 to 4 three-phase capacitors in parallel. The internal connection of the three-phase capacitor of all the &#8220;elements&#8221; of which it is composed is in the form of a star.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The batteries may consist of the following components (depending on the characteristics of the installation):<\/span><\/p>\n<ul>\n<li><span style=\"font-weight: 400;\">Metal enclosure<\/span>.<\/li>\n<li><span style=\"font-weight: 400;\">APR protection fuses<\/span>.<\/li>\n<li><span style=\"font-weight: 400;\">Switching contactor (opt.<\/span>).<\/li>\n<li><span style=\"font-weight: 400;\">Shock ballasts<\/span>.<\/li>\n<li><span style=\"font-weight: 400;\">Capacitors<\/span>.<\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Logically, the existence of these elements depends on the client&#8217;s need and the network topology<\/span>.<\/p>\n<p><span style=\"font-weight: 400;\">Generally speaking, the use of this type of battery is limited to insulation levels of 12 kV and powers from 50 to 1600 kvar \/ 2400 kvar, depending on the operating voltage if it is 6.6 kV or 11 kV<\/span>.<\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last\" style=\"--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-text fusion-text-4 justificado\"><h3><b>Three-phase connection through a double star<\/b>.<\/h3>\n<p><span style=\"font-weight: 400;\">Formed by single-phase capacitors configured in two stars joined by a common neutral. The purpose of this connection is the possibility of incorporating an unbalance protection for the detection of possible internal defects in the capacitors due to the wear and tear and ageing of the equipment or defects that may occur from the electrical network.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Combined with capacitors with internal fuses, not only high safety, but also greater service continuity is achieved<\/span>.<\/p>\n<p><span style=\"font-weight: 400;\">The number of capacitors in the double star depends on the mains voltage and the required battery power. In any case it must always be a multiple number of 3 and never less than 6 units<\/span>.<\/p>\n<p><span style=\"font-weight: 400;\">The batteries may consist of the following components, depending on the characteristics of the installation<\/span>:<\/p>\n<ul>\n<li><span style=\"font-weight: 400;\">Metal enclosure<\/span>.<\/li>\n<li><span style=\"font-weight: 400;\">Gen. switch Automatic in SF6 of maneuvering (opt).<\/span><\/li>\n<li><span style=\"font-weight: 400;\">Shock ballasts<\/span>.<\/li>\n<li><span style=\"font-weight: 400;\">Unbalance current transformer<\/span>.<\/li>\n<li><span style=\"font-weight: 400;\">Capacitors<\/span>.<\/li>\n<li><span style=\"font-weight: 400;\">Unbalance relay (optional<\/span>).<\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Normally used when the configuration up to 12 kV max. voltage is not feasible due to power level (high power of Reactive Energy demanded) or insulation level (insulation voltages higher than 12 kV due to mains voltages of secondary transformers higher than 11 kV).<\/span><\/p>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\" style=\"--awb-bg-size:cover;\"><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-separator\" style=\"margin-left: auto;margin-right: auto;margin-top:30px;margin-bottom:30px;width:100%;max-width:70%;\"><div class=\"fusion-separator-border sep-single\" style=\"--awb-height:20px;--awb-amount:20px;border-color:#558374;border-top-width:2px;\"><\/div><\/div><div class=\"fusion-sep-clear\"><\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:50px;--awb-padding-bottom:50px;--awb-margin-top:50px;--awb-margin-bottom:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first fusion-column-inner-bg-wrapper arriba\" style=\"--awb-inner-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;\"><span class=\"fusion-column-inner-bg hover-type-none\"><a class=\"fusion-column-anchor\" href=\"\/en\/producto\/fixed-hv-capacitors-bank\/\"><span class=\"fusion-column-inner-bg-image\"><\/span><\/a><\/span><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element fusion-image-align-center in-legacy-container\" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><div class=\"imageframe-align-center\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" alt=\"Bater\u00edas fijas de condensadores AT\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-orig-src=\"http:\/\/lifasa.com\/wp-content\/uploads\/bateria-fija-at-categoria.jpg\" class=\"lazyload img-responsive\"\/><\/span><\/div><\/div><div class=\"fusion-text fusion-text-5\"><h5 style=\"text-align: center;\">Fixed HV Banks<\/h5>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-inner-bg-wrapper arriba\" style=\"--awb-inner-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );margin-right: 4%;\"><span class=\"fusion-column-inner-bg hover-type-none\"><a class=\"fusion-column-anchor\" href=\"\/en\/producto\/automatic-hv-capacitors-bank\/\"><span class=\"fusion-column-inner-bg-image\"><\/span><\/a><\/span><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element fusion-image-align-center in-legacy-container\" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><div class=\"imageframe-align-center\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" alt=\"Bater\u00eda autom\u00e1tica de alta tensi\u00f3n\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-orig-src=\"http:\/\/lifasa.com\/wp-content\/uploads\/bateria-automatica-at-categoria.jpg\" class=\"lazyload img-responsive\"\/><\/span><\/div><\/div><div class=\"fusion-text fusion-text-6\"><h5 style=\"text-align: center;\">Automatic HV Banks<\/h5>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last fusion-column-inner-bg-wrapper arriba\" style=\"--awb-inner-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% + 4% ) * 0.33333333333333 ) );\"><span class=\"fusion-column-inner-bg hover-type-none\"><a class=\"fusion-column-anchor\" href=\"\/en\/producto\/banks-with-hv-filters\/\"><span class=\"fusion-column-inner-bg-image\"><\/span><\/a><\/span><div class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"><div class=\"fusion-image-element fusion-image-align-center in-legacy-container\" style=\"text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><div class=\"imageframe-align-center\"><span class=\" fusion-imageframe imageframe-none imageframe-4 hover-type-none\"><img decoding=\"async\" alt=\"Bater\u00edas autom\u00e1ticas con filtro de alta tensi\u00f3n\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" data-orig-src=\"http:\/\/lifasa.com\/wp-content\/uploads\/baterias-filtros-at-categoria.jpg\" class=\"lazyload img-responsive\"\/><\/span><\/div><\/div><div class=\"fusion-text fusion-text-7\"><h5 style=\"text-align: center;\">Filters HV Banks<\/h5>\n<\/div><div class=\"fusion-clearfix\"><\/div><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4293","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>High Voltage Capacitor Banks Technical Note - Lifasa<\/title>\n<meta name=\"description\" content=\"High Voltage Capacitor Banks Technical Note\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"High Voltage Capacitor Banks Technical Note - Lifasa\" \/>\n<meta property=\"og:description\" content=\"High Voltage Capacitor Banks Technical Note\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/\" \/>\n<meta property=\"og:site_name\" content=\"Lifasa\" \/>\n<meta property=\"article:modified_time\" content=\"2018-11-14T14:22:27+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/high-voltage-capacitor-banks-technical-note\\\/\",\"url\":\"https:\\\/\\\/lifasa.com\\\/en\\\/high-voltage-capacitor-banks-technical-note\\\/\",\"name\":\"High Voltage Capacitor Banks Technical Note - Lifasa\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/#website\"},\"datePublished\":\"2018-09-03T10:32:38+00:00\",\"dateModified\":\"2018-11-14T14:22:27+00:00\",\"description\":\"High Voltage Capacitor Banks Technical Note\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/high-voltage-capacitor-banks-technical-note\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/lifasa.com\\\/en\\\/high-voltage-capacitor-banks-technical-note\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/high-voltage-capacitor-banks-technical-note\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/lifasa.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"High Voltage Capacitor Banks Technical Note\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/lifasa.com\\\/en\\\/\",\"name\":\"Lifasa\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/lifasa.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/#organization\",\"name\":\"International Capacitors, S.A.\",\"url\":\"https:\\\/\\\/lifasa.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/lifasa.com\\\/wp-content\\\/uploads\\\/lifasa-logo.png\",\"contentUrl\":\"https:\\\/\\\/lifasa.com\\\/wp-content\\\/uploads\\\/lifasa-logo.png\",\"width\":300,\"height\":85,\"caption\":\"International Capacitors, S.A.\"},\"image\":{\"@id\":\"https:\\\/\\\/lifasa.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"High Voltage Capacitor Banks Technical Note - Lifasa","description":"High Voltage Capacitor Banks Technical Note","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/","og_locale":"en_US","og_type":"article","og_title":"High Voltage Capacitor Banks Technical Note - Lifasa","og_description":"High Voltage Capacitor Banks Technical Note","og_url":"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/","og_site_name":"Lifasa","article_modified_time":"2018-11-14T14:22:27+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/","url":"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/","name":"High Voltage Capacitor Banks Technical Note - Lifasa","isPartOf":{"@id":"https:\/\/lifasa.com\/en\/#website"},"datePublished":"2018-09-03T10:32:38+00:00","dateModified":"2018-11-14T14:22:27+00:00","description":"High Voltage Capacitor Banks Technical Note","breadcrumb":{"@id":"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/lifasa.com\/en\/high-voltage-capacitor-banks-technical-note\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/lifasa.com\/en\/"},{"@type":"ListItem","position":2,"name":"High Voltage Capacitor Banks Technical Note"}]},{"@type":"WebSite","@id":"https:\/\/lifasa.com\/en\/#website","url":"https:\/\/lifasa.com\/en\/","name":"Lifasa","description":"","publisher":{"@id":"https:\/\/lifasa.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lifasa.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/lifasa.com\/en\/#organization","name":"International Capacitors, S.A.","url":"https:\/\/lifasa.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lifasa.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/lifasa.com\/wp-content\/uploads\/lifasa-logo.png","contentUrl":"https:\/\/lifasa.com\/wp-content\/uploads\/lifasa-logo.png","width":300,"height":85,"caption":"International Capacitors, S.A."},"image":{"@id":"https:\/\/lifasa.com\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/pages\/4293","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/comments?post=4293"}],"version-history":[{"count":6,"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/pages\/4293\/revisions"}],"predecessor-version":[{"id":5051,"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/pages\/4293\/revisions\/5051"}],"wp:attachment":[{"href":"https:\/\/lifasa.com\/en\/wp-json\/wp\/v2\/media?parent=4293"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}